4.1 SITE, COVERAGE, MINIMUM FRONT SET BACK, HEIGHT AND F .A.R.
FOR RESIDENTIAL PLOTTED DEVELOPMENT
The proportion upto which a site may be covered with building including
ancillary building along with F .A.R. controls shall be in accordance
with the following slabs, the remaining portion being left open
in the form of minimum front set back, and open spaces around the
building and space at rear, sides or internal courtyard:-
| Sr.No. |
Plot Area (sq. yds.) |
Site coverage |
Minimum front set back |
Height permissible |
F.R.R. |
| 1 |
Upto 100 sq. yds. |
80% |
5'-0" |
38'-6" |
1:2.00 |
| 2 |
Above 100 to 150" |
75% |
6'-0" |
38'-6" |
1:1'.90 |
| 3 |
Above 150 to 200" |
70% |
7'-0" |
38'-6" |
1:1.75 |
| 4 |
Above 200 to 300" |
65% |
10'-0" |
38'-6" |
1:1.65 |
| 5 |
Above 300 to 500" |
60% |
15'-0" |
38'-6" |
1:1.50 |
| 6 |
Above 500" |
50% |
20'-0" |
38'-6" |
1:1.25 |
NOTE: i) Height permissible shall be excluding parapet, water
tank and mumty only.
ii) Minimum clear height for habitable rooms shall be 9'-0"
in every part of
the room.
iii) Open balcony/projection not exceeding 3 ft. in width at the
1st or higher floor levels shall not be included in the covered
area.
iv) The minimum area of a habitable room shall not be less than
100 s. ft.
iv) The minimum area of a habitable room shall not be less than
100 s. ft.
and one side not less than 8 ft. and maximum area of a habitable
room shall not be more than 500 s. ft. and no side more than 30'-0"
v) The arrangement of habitable rooms and other components of a
residential dwelling unit shall be based on sound principles of
planning and I design of a residential .building.
vi) Construction of more than one dwelling unit on each floor in
plotted development shall be allowed provided site coverage, FAR
and height restrictions are adhered to.
vii) No opening is allowed on party wall of properties.
viii) Minimum width of staircase shall not be less than 2'-6".
ix) Minimum ventilation should be 20% of the floor area.
x) The front set-back is exempted in core area: The core area shall
mean, the innermost or the most intimate innerpart of the old city
having a gross density of 250 persons per acre or more, and shall
include all such adjacent areas which are thickly and totally built
up areas and which have assumed same and similar character and notified
as such by the competent authority but shall not include any areas
which are covered under any planned scheme.
xi) Atleast 5% of the space to be left open in or around the building
shall be used for plantation.
xii) Professionals, consultants, doctors, advocates, Architects/Building
Designer and Supervisor can use 10% of covered area for offering
professional consultancy only.
xiii) To facilitate parking and movement of the vehicles, two gates
will be permitted along the accessible road in the front boundary
wall of the residential buildings. In the residential houses the
gate of the standard design and width will be permitted along the
side boundary wall abutting on the accessible street/road.
xiv) Car parking/porch covered with a. fibre glass roof will be
permitted in the front courtyard of the residential house.
xv) In case of plots abutting on two streets other than comer plots,
minimum front set back on both the roads shall be compulsory and
permissible coverage shall be compensated in the form of FAR.
xvi) Construction of access lamps within the street/road portion
shall not beallowed. This will be applicable to all categories of
buildings.
4.2 GROUP HOUSING, MULTI-STOREYED BUILDINGS/APARTMENTS:
| Sr.No. |
Minimum Plot size |
Site coverage |
Maximum F.A.R. |
Maximum Height |
| 1 |
1000 sq. yds. (minimum
size) |
Not exceeding 50% |
1 :2.00 |
59'-6" (excluding
parapet water tank, & mumty, etc.) |
| 2 |
Above 100 sq. yds.
plots |
Not exceeding 50% |
1 :2.00 |
70'-6" (excluding
parapet water tank, & mumty, etc.) |
| |
NOTE: Note: In Group Housing multistoried buildings combination
of compatible mixed landuse is permitted.
4.3 COMMERCIAL:
4.3.1 Site Coverage, Parking, Height and F .A.R.
i) The commercial building activity shall be regulated in accordance
with the provisions regarding site coverage, parking, height and
F .A.R. as per attached schedule- I.
ii) In case of commercial sites located in the Town planning and
Building schemes coverage and zoning shall be in accordance with
the schedule of clauses of the sanctioned scheme.
iii) In case of commercial sites located in the schemes of ITs,
Urban Estates, Indus- trial; Focal Points or scheme prepared under
any other Act and stands transferred to the local bodies, the coverage
shall be regulated by Zoning regulations and Architectural/Building
control sheets applicable to that sanctioned scheme.
4.3.2 Basement:
The construction of basement in commercial buildings shall be governed
in accordance with detailed provisions contained in the Bye-laws
No.4, 7.
4.3.3 Staircase -:
Minimum width of staircase in commercial buildings: The minimum
width of staircase shall be as follows:
| Sr.No. |
Number of Users |
Width of staircase in feet |
| (a) |
Upto 10 persons |
3' -0" |
| (b) |
Between 11 to 20 persons |
3'-6" |
| (c) |
Between 21 to 100 persons |
4' -0" |
| (d) |
Between 101 to 200 persons |
5'-0" |
| (e) |
Above 200 persons |
6'-0" |
4.4 INDUSTRIAL :- Coverage, F .A.R., Height, etc.
(a) Set back lines, ground coverage and height of industrial buildings
in the government approved schemes/industrial focal points transferred
to the local bodies shall be as per approved zoning plans/schedule
of clauses.
(b) In the non-scheme industrial landuse zones ground coverage,
F.A.R. and height shall be regulated in accordance with the schedule-II
and other components shall be regulated as per the provisions of
the factories Act, 1948 and the rules made thereunder.
NOTE:- Residential component in the industrial plot/premises
shall. not exceed 10% of the area of the site and shall be within
the maximum permissible covered area.
4.5 INSTITUTIONAL AND OTHER PUBLIC BUILDINGS (a) In institutional
and other public buildings site coverage shall not exceed 40% of
the total area of the site.
(b) FAR in case of public buildings erected or re-erected for educational
institutions:- shall be 1: 1.0 and in case of other institutional/public
buildings 1: 1.50.
(c) Ground coverage, FAR and height restrictions as applicable to
institutional and other public building sites located in approved
schemes of ITs, Urban Estates and Industrial Focal Point etc. transferred
to the Local Bodies shall be in accordance with the approved Zoning
Plans/Schedule of Clauses.
(d) In case of Institutional and other Public buildings, located
in the Town Planning and Building Schemes site coverage shall be
in accordance with the schedule of clauses of the sanctioned scheme.
4.6 HEIGHT OF BUILDINGS AND SET BACK:-
i) The height of buildings for residential, group housing, commercial,
industrial, institutional and other public purposes shall be regulated
as per the permissible height and F.A.R. restrictions indicated
for such like buildings in the bye-laws besides the Air funnel height
resides the Air funnel height restrictions applicable in the area,
if any.
ii) The width of front set back shall be regulated as per provisions
indicated in respect of residential, commercial and industrial buildings
and also in accordance with the provisions of ground coverage and
F .A.R. restrictions in respect of group housing, institutional
and other public buildings. The side set backs shall be optional.
Where left it shall not be less than 2 metres or 1/6th of the height
of the building whichever is more. The width of the rear set back,
if left at any point of building, it shall not be less than 3 metres
or 1/5th of the height of the building whichever is more.
4.7 PROVISION OF BASEMENTS IN BUILDINGS
i) Basement shall be the storey which is next below or immediate
below the ground storey or which may be in any part of the plot
within building envelope line and upto maximum coverage not more
than coverage on ground floor. The minimum height of the basement
for habitable purposes shall not be less than 9'-0" from the
floor to the ceiling of the basement and in each part 8' clear height
in case of beam structure or frame-structure or otherwise and minimum
height of the basement for parking purposes shall not be less than
10' from the floor to the ceiling of the basement and in each part
8'-6" clear height in case of beam or frame structure.
ii) The ground floor level of the basement shall not be less than
3 '-6" from the adjoining average ground level for adequate
light and ventilation.
iii) Single basement is allowed in all residential, commercial,
industrial, and group housing plots. However, on commercial and
institutional plots having area more than 1000 sq. yds., more than
one storey basement may be allowed, if all other conditions for
structural stability are fulfilled and it shall be exclusively used
for parking.
iv) Basement may be used for commercial purpose, Banquet Hall etc.
if it is air conditioned. It shall have minimum either two stair-cases
for entry and exit or two approach ramps or one stair case and one
ramp and total F.A.R. not exceeding more than 1:2.00. In case in
commercial building F.A.R. is exceeded more than 1:2.00 then single
basement shall be compulsory and shall be used for parking purpose
only in addition to open space provided for parking on ground level
v) However, 10% of the basement area would be increased to a depth
of 14'-0" for the purpose of installation of electric-generator
or air-conditioning plant or providing a room for lift to the basement
storey.
vi) Applicant/Building Designer and Supervisor shall submit the
certificate regarding its structural safety in relation to underground
water table/spring level,
vii) Adequate arrangement shall be made so that surface drainage
does not. enter the basement.
viii) Applicant/owner of the building shall install suitable pumps
for pumping the waste water into the sewer in place of directly
connecting it to the sewer to. avoid any risk of the sewerage or
sullage heading back into the basement at any time.
ix) Basement for parking shall not be taken into account for F.A.R.
)
x) Indemnity Bond for basement as per Schedule-III shall be given
by the applicant along with notice of building application to indemnify
the local authority" in case of any loss or damage caused to
the adjoining properties on account of construction of basement
either at the time of digging of its foundation or during the course
of its construction or even there after and also against any claim
of any concern thereto.
xi) In case on the side of the site there is single storey building
then 5'-0" side space is required from the adjoining property.
xii) If on the side of the site there is double storey building
then 7'-6" side space is required
xiii) If on the side of the site there is more than two storey building
then 10'-0" side space is required.
xiv) If the applicant/owner does not leave side space according
to above requirements he shall produce NOC from the owners of adjoining
properties.
xv) The permissible covered area for basement will be the same as
the permissible coverage on ground. However, permissible coverage
can be increased in the basement to create parking space on the
following conditions:
(3.) The roof level of such part of the basement shall not be raised
above the surrounding ground level.
(b) Clear ceiling height of such part of the basement shall not
be less than 7'-0".
(c) Mechanical arrangement shall be made for exhaust.
(d) Sufficient additional arrangements shall be made for fire safety
to the satisfaction of Fire Officer.
xvi) Ramp in basement for parking purpose shall be of a minimum
width of 9'-0" with gradient of 1 in 7.
xvii) Parking areas including basement and covered parking shall
be exclusive public parking areas maintained by the builder/promoter
upto the satisfaction of local authority.
Note: In case of double basement side space requirements
shall be double as detailed in xi, xii, and xiii above.
4.8 PROJECTION: (1) Where there is an uncovered balcony or
chhajja or cantileaver from wall it shall not project more than
two metres beyond the building line when measured right angle to
the outerface of the wall and it shall be within the boundaries
of the site and in case of row houses or buildings adjoining each
other the projection shall not be more than one metre in case the
area of the site is less than 250 square metres.Provided that projection
on door and window shall not exceed 0.45 metres.
(2) No projection shall be at a lesser height than 2.25 metres clear
above the plinth level of the building
(3) The width of the projection shall not exceed the one forth of
the width of the set. Backs and side spaces.
(4) The area of projection upto 3' shall not be counted towards
the covered area of the site.
4.9 PROVISION OF LIFTS IN BUILDINGS
Every building having more than fifteen metres height shall be provided
with a minimum of one lift and total number of such lifts shall
be calculated on the basis of one lift for every 900 square metre
floor area above four storeys.
|